FA Flange Electromagnetic Flow Meter

Brand: FLOWTECH
FLOWTECH FA Flange Electromagnetic Flow Meter, ISME Malaysia
  • Whole welded structure
  • Good sealing performance
  • Zero-point stability
  • Small power consumption
  • Simple and reliable, no moving parts inside; virtually no pressure loss
  • Low-frequency square-wave
  • Anti-jamming performance
  • User friendly, easy maintenance
  • SPAN approved product
Diameter:   DN10 to DN2000
Electrode:  Hastelloy C / SS316L / Hb / Ti / Pt / Ta
Liner:  PTFE / Hard Rubber / F46 / PFA / Ceramic
Body: Carbon steel (option : stainless steel)
Conductivity:  ≥ 5μ s/cm / Softened water ≥ 20μ s/cm
Accuracy :  ±0.5% R.S
Operating temperature:   -20 to 80˚C (Compact) / -20 to 120˚C (Remote)
Operating pressure:  Max 16 Bar / 10 Bar / 6 Bar (based on diameter)
Protection class:  IP67 (compact) / IP68 (remote)
Output:  4-20mA / Frequency / Pulse output signal
Communication:  RS485 Modbus / HART (as option)
Power supply:   220V AC / 24V DC
Connection:  DIN flange PN16 / PN10 / PN6 / JIS 10k / ANSI 150#
Installation type:  Vertical / Horizontal with full-bore flow condition
Converter type:  Compact type (integral sensor) / Remote type (Non-attached sensor)
Cable length:  Remote converter with 10 meters cable (standard)

The Flowtech FA series electromagnetic flow meter consists of grounding electrode where grouding rings is not required. It can be used to accurately measure the flowrate of liquid-solid two phase fluids, such as sewage, paper pulp, slurry and mineral slurry which has an electrical conductivity greater than 5 μS/cm. This type of flowmeter is practically unaffected by variation in temperature, viscosity, pressure and density. There is no pressure loss and no moving parts which will not cause additional energy losses or trapped with solid waste. With bi-directional feature, the flow indication and totalization in both directions is standard.

A compact design integrates the converter and flow sensor while remote type comprises of remote mounted converter and flow sensor connecting with signal cable.

With RS485 Modbus communication, the FA series flowmeter is able to connect to the REMOX for remote monitoring function.