- Designed for aggressive fluids
- Direct reading indicator
- From DN 50 up to DN 200 pipes
- Scale amplification from 2 to 10
- Mounting in all positions
- Standardized with NF X 10-102 Norm
- Accuracy ±2.5% full scale
- Option: Electrical switch counter
Measuring range: | From 2 to 350 m3/h (water) |
Accuracy: | ±4% |
Repeatability: | ±0.4% |
Scale amplitude: | 2 to 10 |
Pressure limit: | 10 bar (water at 20°C) |
Temperature limit: | 50°C (PVC) / 90°C (PPH) / 120°C (PVDF) |
Pressure drop: | On request |
Orifice plate material (standard): | PVC |
Associated flow indicator material: | PVC or polysulfone |
Diver material: | PVDF |
Bypass material: | Same as the orifice plate |
Stop valves material: | Same as the orifice plate |
Seals material: | EPDM |
BORDA injector material: | PVC, PPH or PVDF |
Diaphragm is inserted between 2 flanges in the main duct. The differential pressure is transmitted to the exterior via 2 pressure ports on each diaphragm face. This pressure is proportional to the flow rate square in circulation inside of the duct. A flowmeter, mounting in derivation allow a direct reading of the flow rate. To obtain a strictly proportional to the main flow rate, a BORDA injector is insert before or after flowmeter.
This flowmeter can be replaced by a counter, allowing a totalization. Orifices can be only delivered in stainless steel 316L, or with pressure ports directly on steel or stainless steel. Their accuracy is 1%, diameters are from 50 and 60 mm. We supply flowmeter with special graduation for derivated measure on all existing diaphragm, only if specifications are given before graduation.