- Continuous turbidity measurement according to ISO 7027: 90° scattered light measurement and 180° attenuated light measurement
- Smooth cell surfaces – no settling of particles
- Measurement ranges:
- 0.01 to 20 FNU
- 0.1 to 500 FNU & 100 to 1000 FAU
- Output signal: 4-20 mA
- Process connections: Flanges or unions
- Applications: Well water monitoring; monitoring of filtering or reverse osmosis units; control of the sewage plant outlet; cooling water monitoring; filter clogging monitoring
Power supply: | 24 V DC stabilized (10 to 30 V DC) |
Consumption: | 0.5 to 1 W |
Probe current: | 4-20 mA |
Ambient temperature: | +5 to +45 °C |
Liquid temperature: | PVC: +5 to +60°C PPH: +5 to +80 °C |
Pressure limits: | Max. 6 bar at 20°C (PVC and PPH) and 1 bar at 60 °C (PVC and PPH) |
Measuring cell: | PVC or PPH |
Connection head: | PBT housing (glass fiber reinforced); IP 65 according to EN 60529 |
Sealings: | EPDM (others on request) |
Optical windows: | Borosilicate glass, Cleanosil coating |
Accuracy: | ±5 % of reading, ±1 % of full scale in use |
Resolution: | 0.001 to 0.2 FNU depending of scale in use |
Process connections: | PVC unions, solvent welding PPH unions, fusion welding Flanges |
BAMO Turbicube (PVC) Inline Transmitter measures the turbidity of the liquid using attenuated light beam (at 180°) and a scattered light beam (at 90°) with a 860 nm wavelength light, according to european standard ISO 7027. The measurement system integrates an assembly with 2 emitters and 1 receiver with a micro-processor in the main housing. The 4-20 mA output signal corresponds to the selected scale in use.
- Turbicube 20: 5 scale ranges to select by DIP switches from 0.01 to 1 up to 0.01 to 20 FNU
- Turbicube 1000: 5 ranges to select by DIP from 0.1 to 500 FNU and 100 to 1000 FAU
Mounting: Only for vertical fully loaded pipe, with ascending flow. Slow down sections: 600 mm before device and 400 mm after device.