- Super low flow measurement down to 2m/s
- Self-diagnose function
- Unique dual-sensor technology
- Anti-vibration feature
- Self density calculation function (optional)
- Multi-variable version with built-in RTD and pressure sensor
- Unit selectable function
- Communication via bluetooth and APP (optional)
- Password protection
Process connection: | Flange: DN15 to DN300 (0.5” to 12”) Wafer: DN15 to DN300 (0.5” to 12”) |
Sensor: | Anti-vibration vortex sensor |
Power supply: | 4 to 20mA (2 wire): 13.5 to 42V VFM60MV with 4 to 20mA (2 wire): 15.5 to 42V Modbus RTU: Current Iq < 9mA 13.4 to 42V |
Communication: | HART (V5, V7) / Modbus-RTU / Pulse |
Protection: | Explosion proof |
Medium temperature: | Standard: -40 to 150°C Medium: -40 to 350°C High: -40 to 150°C |
Flow rate (m3/h): | Liquid: ±0.75% RD (Re ≥ 20000); ±2% RD (10000 < Re < 20000) Gas/steam: ±1% RD (Re ≥ 20000); ±2% RD (10000 < Re < 20000) |
Mass flow (kg/h): | Gas/steam: ±1.5% RD (Re ≥ 20000); ±2.5% RD (10000 < Re < 20000) |
Repeatability: | ±0.3% |
Gas turndown ratio: | 1:30 |
Steam turndown ratio: | 1:35 |
Liquid turndown ratio: | 1:10 |
Upstream/downstream: | 15xD / 5xD |
Viscosity allowance: | DN15: ≤ 4mPas DN25: ≤ 5mPas DN40 to DN300: ≤ 7mPas |
Pressure allowance: | 1.6MPa (232 psiG) 2.5MPa (362 psiG) 4.0MPa (580 psiG) 6.3Mpa (913 psiG) |
Comate VFM60 is a powerful flow meter utilizing “Karman vortex” theory, which can meet the requirement of measuring the flow rate of various fluids such as gas, steam and liquid. The product has an excellent signal processing capability, with lower measuring limit, better stability and accuracy. The digital transmitter support communication via bluetooth and APP which allows users to access and diagnose the meter remotely, on a smart device. The unique dual-sensor design and special signal processing method eliminates vibration signals to provide a reliable performance. The VFM60 series is a highly customisable product, allowing upgrades and customisation according to specific requirements.
Process fluids: Liquid, natural gas, biogas, saturated steam, superheated steam applications, etc. Fluids must be homogeneous and single-phase.
Measurable parameter:
Standard version: Volume flow rate in pipe, velocity (Can measure mass flow rate, temperature and pressure if wired to separate RTD and pressure transmitter.)
Multi-variable version: Mass flow rate, volume flow rate in standard condition, temperature, pressure, volume flow rate in pipe, velocity.