Skip to content

IUNI-21 2-Channel Blue-Green Algae Analyzer

Brand: PROBEST
I-SYSTEM IUNI-21 2-Channel Blue-Green Algae Analyzer, ISME Malaysia
  • RS485 signal output
  • Optical fluorescent measurement technique
  • Identify pigment before it is affected by potential water bloom
  • Requires no extraction or other treatment, rapid detection to avoid the impact of long shelving the water sample
  • Stable data and good repeatability
  • Direct and continuous measurement
  • Strong anti-interference ability
  • Fast response time
  • Low maintenance cost
  • Suitable for wide range of application such as water treatment plant (inlet), drinking water resources and aquacultural

B800 Series Digital Blue-Green Algae Sensor

Measuring range:  100 to 300,000 cells/mL
Pressure range: ≤0.4Mpa
Measuring temperature:  0 to 45°C
Requirements:  Suggest a multipoint monitoring for the distribution of Blue-Green Algae in water that is very uneven. Water turbidity is below 50NTU.
Accuracy:  ±5% of the signal level corresponding value of 1ppb Rhodamine WT Dye
Calibration:  Deviation value calibration; Slope calibration
Communication:  RS485 (Modbus)
Dimension:  Diameter 38 mm, Length 245.5 mm
Protection:  IP68 / NEMA 6P
Sensor material:  SUS316L + PVC
Signal cable length:  Standard 10 meter
Storage temperature:  -15 to 50°C

IUNI-21 Dual Channel Analyzer

Display:  160*160 LCD with backlight
Power supply:  AC: 85-500V AC, 50/60Hz
DC: 9-36V DC (upon request)
Analogue output : 3 x 4-20mA
Relay output:  3 x relay output (programmed response parameters and value)
Communication protocol:  RS485 (Modbus)
Ambient temperature: -20 to 70°C
Operation temperature:  -15 to 60°C
Protection:  IP65 / NEMA 4X
Device weight:  1.35 kg
Device dimension:  145 (H) x 125 (W) x 162 (D) mm
Enclosure:  PA66+GF25+FR (Cover); Aluminium alloy powder (Lower casing)
Parameter:  Blue-green algae

The B800 series online optical digital blue-green algae sensor’s principle uses the characteristics of cyanobacteria who has absorption peaks and emission peaks in the spectrum. The absorption peaks emit monochromatic light into the water, cyanobacteria in the water absorbs the energy of monochromatic light, releasing monochromatic light of emission peak of another wavelength. The light intensity emitted by cyanobacteria is proportional to the content of cyanobacteria in water.

The IUNI-21 dual channel analyzer is an effective option that can connect two digital blue-green algae sensors at the same time to reduce the cost of transmitter and installation space.

  • Field mounted dual channel analyzer with datalogger
  • Connect two sensors at one time
  • 4-20mA output
  • Relay output
  • Communication, RS485 (Modbus)
  • LCD visual display
  • User friendly and attractive operating interface

Price (subject to change) includes 1 x IUNI-21 Universal Transmitter and 1 x B800 Series Digital Blue-Green Algae Sensor.