- For clear liquids
- Stainless steel or brass versions
- For pipes from DN 50 up to DN 200
- Mounting on-line, fitting with loose nut BSPF ½”
- Applications: Detection of the presence or not of flow in a pipe under pressure. The liquid must be free of magnetic particles.
Materials: | Body and fitting in AISI 316 Ti with FPM seals Body and fittings in brass with NBR seals |
Fittings: | Male thread BSP ½” |
Size: | From DN 50 up to DN 200 mm |
Temperature limits: | Liquid: -25 to 110 °C Ambient: -25 to 80 °C |
Pressure limit: | PN 25 |
Contact: | N.O. or N.C. (according terminals) |
Operation: | Flow below the switching point: Open contact Flow over the switching point: Closed contact Possibility to reverse the logic |
Current limit: | Max. 1 A |
Voltage limits: | Max. 230 V AC, 48 V DC |
Switching power: | Max. 26 VA, 20 W |
Switching point: | ± 15 % of table values |
Protection: | IP 65 |
Connector: | Plug DIN EN 175301-803-A |
The flow of liquid drives the paddle which actuates a Reed contact via a magnet mounted on the top of the paddle. A second magnet in opposition, pushes back the paddle when flow is decreasing. This design allows the CDP 57 controller to be mounted in any position.
Mounting precautions: Mounting could be on a vertical pipe with ascending flow; Then, threshold value will be greater than the one of table. The pipe slope of a flowing down piping must be less than 40 %.
Note: An amplifier relay ES 2001 will protect the Reed contact and allows a switching power of up to 500 VA / 250 V AC / 5 A – 1 A / 125 V DC / 40 W).