- Color touch screen
- Display of level, flow-rate, daily volume and totalization
- Flowrate tables for Venturi and weir plates
- 1 Input 4-20mA and 1 input Pt 100 Ohm
- 2 analogue outputs 0/4-20 mA
- 4 programmable relay outputs; 2 as alarms, 1 for sampler, 1 for pulse output)
- Options:
- RS 422 /J-BUS + LOGGER
- Extension terminal for a second measurement input
End-user interface: | Color touch screen 4.3”, resolution 480×272 pixels Display of measurements, menus, temperature, relay status Configuration – Keyword protected |
Measuring scales: | Height of liquid (mm) – Resolution 1 mm Flow-rate (m³/h) – Resolution 0.1 m³/h Volume (m³) – Resolution 1 m³ |
Volumes and totalization: | Daily volume – on 8 digits – Reset to zero through the menu Totalization – on 8 digits – No reset to zero |
Measurement signals inputs: | 4-20 mA proportional to height of liquid Temperature Pt 100 Ω sensor (-20 to 160 °C) |
Memorized flow-rate tables: | In memory for Venturi channels, weird plates in V or U |
Thresholds S1 and S3: | contacts N.O., potential free, dedicated to flow-rate or temperature or to an external sensor. Adjustable hysteresis from 0 to 100 % – Adjustable timer from 0 to 9999 s |
Sampler monitoring S2: | Set up on volume (m³) 1 contact N.O., potential free. Adjustable timer (closed contact) from 0 to 9999 s |
Pulse output S4: | For external counter – 1 pulse/m³ 1 contact N.O., potential free |
Contact initial resistance: | 100 mΩ max. (voltage drop 6 V DC 1 A) |
Switching power: | 3 A, 277 V AC; 3 A, 30 V DC (nominal) |
Switching capacity (min.): | 100 mA, 5 V DC (variable according to switching frequency, ambient conditions, accuracy) |
Measurement output: | 0/4-20 mA (max. 600 Ω) proportional to flow-rate – Programmable scale Temperature (°C) |
Main power supply: | 230 V AC – 50/60 Hz (others on request) – Consumption 10 VA |
Models: | Panel mounting, 96×144 mm; Front IP65; Rear IP40 Wall mounting, IP65, with cable glands |
Option (RS 422 + Logger): | Interface: RS422 output, J-BUS link – Binary slave mode – 2400 to 9600 bauds Data Logger: Record of cycle average measurement – 150 000 records max. on memory card. |
Bamophar 759 flow calculator for open channel converts the input signal directly into flowrate, through a calculator and using formulas and calibration tables of our Venturi channels (ISO 4359) and our standard V or U channel weirs.
The reading is easy on the 4.3″ color touch screen for flow-rate or height of liquid, as well as for totalization. Through a user friendly menu, settings are easy for thresholds, alarms, sampler monitoring and all parameters.
Extension terminal (panel, wall or DIN rail mounting):
- Allows a second measurement (Turbidity, pH, Conductivity, etc.) Data from this blind unit are displayed on the main device
- Connected to main unit with a 2×2-wire shielded cable (Cable length between both devices: max. 500 m)
- Extension terminal uses the RS 422 and data logger of main unit