![BAMO Mesures GAD531 Level Detection Grease Water Separators, ISME Malaysia](https://i0.wp.com/ismesb.com/Gamma/wp-content/uploads/2023/02/512005-GAD-531.jpg?fit=800%2C800&ssl=1)
- Monitoring of grease-water separators
- Compact and economical model
- Detection of grease layer thickness overpassed
- Relay output; Changeover contact
- LEDs signals and audible alarm
- Alarm unit for monitoring of grease separators in conformity with EN 1825
Main power supply: | 230 V AC +/- 10 % ; 50/60Hz |
Power consumption: | ~ 2 W |
Housing protection: | IP65, according EN 60529 |
Operating temperature: | -20 to +60°C |
Monitoring: | The device has an auto-diagnostic of measuring loop integrity (broken cable, short-circuit) |
Signals and alarm: | Audible alarm (Buzzer) Green LED for normal status Yellow LED when alarm occurred and not yet reset Red LED for alarming status |
Control: | Through 1 push button for diagnostic test and alarm acknowledgement |
Relay output: | 1 Relay, 230 V AC, 3 A Changeover contact; Potential free |
Cabinet: | Housing: Polycarbonate; 120x80x55 mm; IP 65; Wall mounting |
GP/10 – Grease layer probe (Only for use with an alarm unit GAD 531): | |
Materials: | PP, PE and stainless steel |
Cable: | 10 m long; Elastomer resistant to oils; 2-wire cable (2 x 1 mm²) |
Max. length: | 300 m (adding an extension with a junction connector) |
Dimensions: | Ø 32 mm; Stem length: 200 mm |
Protection: | IP 68 acc. EN 60529 |
Measuring principle: | Capacitive, high frequency |
Operating temperature: | -20 °C to +60 °C |
BAMO GAD 531 and probe GP/10 are designed for monitoring grease-water separators. The probe GP/10 detects when the thickness of floating greases over water, is greater than the permitted maximum thickness:
- Yellow LED: Alarm occured, not yet reset
- Green LED: Normal monitoring status
- Red LED: Alarming status
The alarm unit has an auto-diagnostic of system integrity. A relay output and an audible alarm inform the operator. The buzzer may be deactivated with a simple jumper if necessary.
Components of one system:
- Alarm unit GAD 531
- Detector: Probe GP/10 (cable output, 10 m long)
Caution: Not suitable for the detection of greases in emulsion, or greases cured in aggregate