- Color touch screen
- Available scales: 0.001 to 9999 FNU, FAU, NTU, mg/l, g/l
- 2 outputs 0/4-20mA (measurement & T.°C)
- 3 Independent relays
- 1 Relay for alarming function
- Options:
- RS 422 /J-BUS + Logger
- Extension terminal for a 2nd measurement parameter
End-user interface: | Color touch screen 4.3”, resolution 480×272 pixels Display of measurements, menus, temperature, relay status Configuration – Keyword protected |
Measuring scales: | To set up according the turbidity transmitter in use (from 0.001 to 9999 FNU, FAU, NTU, mg/l, g/l) |
Sensor signal input: | For Turbidity transmitter 4-20 mA, 2-wire or 4-wire technique |
Temperature display: | Input signal for Pt 100 Ω 3-wire sensor, within the range 0 to 100 °C Input signal for Pt 100 Ω 3-wire sensor, within the range 0 to 100 °C |
Relay outputs: | 4 contacts N.O., potential free |
Configurable thresholds: | 2 Independent thresholds, for measurement or temperature 1 Independent threshold, for measurement or temperature or to external function 1 threshold for alarming function (Temperature sensor fault) or measurement out of range |
Contact initial resistance: | 100 mΩ max. (voltage drop 6 V DC 1 A) |
Switching power: | 831 VA AC / 3 A / 277 V AC 90 W / 3 A / 30 V DC |
Switching capacity (min.): | 100 mA, 5 V DC (variable according to switching frequency, environmental conditions and accuracy). |
Measurement output: | 0/4-20 mA (max. 600 Ω) proportional to measurement |
Temperature output: | 0/4-20 mA (max. 600 Ω) within the range 0 to 100 °C |
Measurement output: | 0/4-20 mA (max. 600 Ω) proportional to flow-rate – Programmable scale Temperature (°C) |
Main power supply: | 230 V AC – 50/60 Hz (others on request) – Consumption 10 VA |
Models: | Panel mounting, 96×144 mm; Front IP65; Rear IP40 Wall mounting, IP65, with cable glands |
Storage: | -10 to +70 °C |
Operating temperature: | -5 to +50 °C |
Option (RS 422 + Logger): | RS422 output, J-BUS link – Binary slave mode – 2400 to 9600 bauds Data Logger; Record of cycle average measurement – 150 000 records max. on memory card |
Bamophar 436 turbidity monitor is equipped with a color touch screen to set up the configuration and to display the turbidity, temperature and state of thresholds. Copies of measurement are available on 2 outputs 4-20 mA.
Bamophar 436 displays the turbidity value measured by one of our transmitters, to respond to process requirements.
- Turbicube in PVC or PPH and Trubomat GAB in stainless steel, are dedicated to in-line measurement.
- Turbisens in PVC is an immersion probe with transmitter for measurements in tanks, basins, channels.
A complete measuring system includes a Bamophar 436 monitor and a turbidity transmitter
Option: Extension terminal for a second parameter
- Allows a second measurement (pH, Flow rate, Conductivity,etc.) (Configuration and display on the main unit)
- Connected to main unit with 2 x 2-wire shielded cable (Cable length between both devices: max. 500 m)
- RS422 and Data Logger of main unit are shared between both units
- Wall or panel or DIN rail mounting: according to the model