Bamophar 216 Monitor And Recorder
- Lead Time: 4~6 weeks

⚠ Attention: Discontinued product
- Color touch screen
- 1 Sensor input, 0/4-20 mA
- Display without or with measuring unit: m; cm; %; ppm; mg; g; °C; _ (none)
- 1 Pt100 sensor input
- 2 Outputs 0/4-20 mA (measurement & T °C)
- 4 Relay outputs (thresholds, alarm and/or regulation)
- Options:
- RS 422 /J-BUS + Logger
- Extension terminal for a 2nd measurement parameter
End-user interface: | Color touch screen 4.3”, resolution 480×272 pixels Display of measurements, menus, temperature, relay status Configuration – Keyword protected |
Measuring scales: | To configure with 4 digits (-9999 to +9999) according the sensor in use |
Measurement units: | m; cm; %; ppm; mg; g; °C; _ (none) |
Accuracy: | According to the sensor in use |
Sensor input: | For transmitter with 0/4-20 mA output |
Temperature sensor input: | For a Pt 100 Ω sensor, 3-wire, measurement and reading from -20 to 160 °C |
Relay outputs: | 4 contacts N.O., potential free |
Thresholds set up: | S1, independent, dedicated to measurement or to temperature S2, independent, dedicated to measurement or to temperature S3, independent, dedicated to measurement or to temperature or, to external function S4, threshold in alarm function, measurement out of range or broken loop |
Hysteresis: | Adjustable from 0 to to 100 % for S1, S2 and S3 |
Contact initial resistance: | 100 mΩ max. (voltage drop 6 V DC 1 A) |
Switching power: | 831 VA AC / 3 A / 277 V AC 90 W / 3 A / 30 V DC |
Switching capacity (min.): | 100 mA, 5 V DC (variable according to switching frequency, environmental conditions and accuracy). |
Mechanical lifetime (min.): | 5 x10⁶ operations (180 op./min) |
Electrical lifetime (min.): | 2 x 10⁵ (at 20 op./min) for 3 A, 125 V AC; 3 A, 30 V DC – 10⁵ (estimated load) for 3 A 125 V AC |
Measurement output: | 0/4-20 mA (max. 600 Ω) proportional to measurement |
Temperature output: | 0/4-20 mA (max. 600 Ω); expandable to any scale, to match external PLC settings |
Main power supply: | 230 V – 50/60 Hz (others on request) – Consumption 10 VA |
Models: | Panel mounting, 96×144 mm; Front IP65; Rear IP40 Wall mounting, IP65, with cable glands |
Option (RS 422 + Logger): | RS422 output, J-BUS link – Binary slave mode – 2400 to 9600 bauds Data Logger; Record of cycle average measurement – 150 000 records max. on memory card |
⚠ Attention: Product has been discontinued. You are currently viewing old documentation. Please use with caution.
Bamophar 216 allows a local control of a process as well as the recording of measurements with the option logger.
Bamophar 216 is equipped with a color touch screen for the display of a multilingual menu friendly and intuitive. It provides easy reading of measurement, temperature and state of the thresholds. The device displays all the menu to set up analogue outputs, thresholds and function modes. In order to facilitate its commissioning, a programming menu can simulate the measurement, acting on the measurement analogue outputs and on the thresholds.
The analogue output, copy of measurement, may be scaled on any range. Temperature measurement is available on the second analogue output 4-20 mA.
An extension terminal (wall, panel or DIN rail mounting):
- Allows a second measurement parameter (pH, flow, conductivity, etc.) (Displays and settings are achieved through the main unit)
- Connected with a 4 shielded wire cable to the main unit (Max. length is 500 m)
- Extension terminal uses the RS 422 and logger device of main unit