Skip to content

Bamophar 364 Conductivity Meter For Inductive Probe

Brand: BAMO
BAMO Mesures Bamophar 364 Conductivity Meter For Inductive Probe, ISME Malaysia
  • Color touch screen
  • Measuring range, 4 scales: 0 – 2 mS/cm up to 0 – 2000 mS/cm
  • Automatic temperature compensation
  • 2 outputs 0/4-20mA
  • 3 Independent relays
  • 1 Relay for alarming function
  • Options:
    • RS 422 /J-BUS + Logger
    • Extension terminal for a 2nd measurement parameter
End-user interface:  Color touch screen 4.3”, resolution 480×272 pixels
Display of measurements, menus, temperature, relay status
Configuration – Keyword protected
Measuring scales:  10 μS/cm up to 2000 mS/cm
0 to 2 mS/cm; 0 to 20 mS/cm; 0 to 200 mS/cm; 0 to 2000 mS/cm
Accuracy:  ± 0.3 %; ± 0.3 °C
Probe input:  On screw connectors
Temperature compensation:  Automatic with Pt 100 signal, sensor built-in the inductive probe.
Manually between 0 and 100 °C
Relay outputs:  4 contacts N.O., potential free
Configurable thresholds:  S1, independent threshold, to set up for measurement or temperature
S2, independent threshold, to set up for measurement or temperature
S3, independent threshold, to set up for measurement or temperature or external function
S4, to set up for alarming function: out of range or broken cable
Contact initial resistance:  100 mΩ max. (voltage drop 6 V DC 1 A)
Switching power: 831 VA AC / 3 A / 277 V AC
90 W / 3 A / 30 V DC
Switching capacity (min.):  100 mA, 5 V DC (variable according to switching frequency, environmental conditions and accuracy).
Mechanical lifetime (min.):  5 x 10⁶ operations (180 op./min)
Electrical lifetime (min.):  2 x 10⁵ (at 20 op./min) for 3 A 125 V AC, 3 A 30 V DC – 10⁵ (estimated load) for 3 A 125 V AC
Measurement output:  0/4-20 mA (max. 600 Ω) proportional to flow-rate – Programmable scale
Temperature (°C)
Main power supply:  230 V AC – 50/60 Hz (others on request) – Consumption 10 VA
Models:  Panel mounting, 96×144 mm; Front IP65; Rear IP40
Wall mounting, IP65, with cable glands
Option (RS 422 + Logger):  RS422 output, J-BUS link – Binary slave mode – 2400 to 9600 bauds
Data Logger; Record of cycle average measurement – 150 000 records max. on memory card

Bamophar 364 is designed for conductivity measurement for monitoring and/ or regulation in water treatment, chemical industries, industrial applications (ie. cooling towers survey; clean water control (wells, drinking water, thermal baths); stormwater and runoff water survey; WWTP survey; concentration measurements of acid and base; chemicals quality survey; and display in concentration of NaCl, NaOH or HCl).

Bamophar 364 displays on a color touch-sensitive screen a multilingual friendly using menu. The reading is easy for measurement, temperature and relay status. Conductivity and temperature values are available as well from outputs 4-20 mA.

With inductive probes TCS3020 or TCSS50, Bamophar 364 allows measurements from 10 μS/cm up to 2000 mS/cm all along process routines.

A complete measuring system includes:

  • 1 Inductive probe, cable output
  • 1 Probe holder for immersion or on-line application
  • 1 Converter, factory calibrated
  • 1 Monitor Bamophar 364

Option: Extension terminal for a second parameter

  • Allows a second measurement (pH, Flow rate, Conductivity,etc.). Data from this blind unit are displayed on the main unit.
  • Mounting: wall or panel versions
  • Connected to main unit with 2 x 2-wire shielded cable (Cable length between both devices: max. 500 m)
  • RS422 and Data Logger of main unit are shared between both units