Skip to content

Bamophar 323 Conductivity/Resistivity Meter

Brand: BAMO
BAMO Mesures Bamophar 323 Conductivity/Resistivity Meter, ISME Malaysia
  • Color touch screen
  • Programmable ranges: From 0-200 Ω .cm up to 0-200 MΩ .cm; From 0-2 μS/cm up to 0-20 mS/cm
  • Associated measuring cells: Cell factors: 10 – 1 – 0.1 – 0.01
  • Temperature compensation: Automatic or manual compensation
  • 2 outputs 0/4-20 mA, configurable
  • 4 relays (Thresholds, alarm)
  • Options:
    • RS 422 /J-BUS + Logger
    • Extension terminal for a 2nd measurement parameter
End-user interface:  Color touch screen 4.3”, resolution 480×272 pixels
Display of measurements, menus, temperature, relay status
Configuration – Keyword protected
Measuring scales:  From 0-2 μS/cm up to 0-20 mS/cm or from 200 Ω.cm up to 200 MΩ.cm
Accuracy:  ± 0.3 %; ± 0.3 °C
Connection of probe:  With a BNC connector
Temperature compensation:  Automatic with Pt 100 signal, sensor built-in the inductive probe.
Manually between 0 and 100 °C
Relay outputs:  4 contacts N.O., potential free
Configurable thresholds:  S1, independent threshold, to set up for measurement or temperature
S2, independent threshold, to set up for measurement or temperature
S3, independent threshold, to set up for measurement or temperature or external function
S4, to set up for alarming function: out of range or broken cable
Hysteresis:  To set up between 0 and 100 % on S1, S2 and S3
Contact initial resistance:  100 mΩ max. (voltage drop 6 V DC 1 A)
Switching power: 831 VA AC / 3 A / 277 V AC
90 W / 3 A / 30 V DC
Switching capacity (min.):  100 mA, 5 V DC (variable according to switching frequency, environmental conditions and accuracy).
Measurement output:  0/4-20 mA (max. 600 Ω) proportional to flow-rate – Programmable scale
Temperature (°C)
Temperature output:  0/4-20 mA (max. 600 Ω), for all scales from 0 to 100°C
Main power supply:  230 V AC – 50/60 Hz (others on request) – Consumption 10 VA
Models:  Panel mounting, 96×144 mm; Front IP65; Rear IP40
Wall mounting, IP65, with cable glands
Storage:  -10 to +70 °C
Operating temperature:  -5 to +50 °C
Option (RS 422 + Logger):  RS422 output, J-BUS link – Binary slave mode – 2400 to 9600 bauds
Data Logger; Record of cycle average measurement – 150 000 records max. on memory card

Bamophar 323 is designed for conductivity or resistivity measurements ie. conductivity on drinkable and ground water; conductivity in cooling tower; resistivity on demineralized water; and control of ultra pure water production units.

Bamophar 323 device is equipped with a color touch screen for the display of a multilingual menu friendly and intuitive. It provides easy reading of measurement, temperature and state of the thresholds.

It displays a menu with all parameters for configuration of analogue outputs,thresholds set up and regulation mode. In order to facilitate its commissioning, a programming menu can simulate the measurement, acting on the analog outputs, as well as on the thresholds.

Associated measuring cells have cell factors from 0.01 up to 10 for accurate measurements between 0 to 2 μS/cm and 20 mS/cm or O to 200 Ω.cm and 200 MΩ.cm.

Bamophar 323 displays an absolute or compensated temperature measurement (Access to two reference charts: 20 °C and 25 °C).

Option: Extension terminal for a second parameter

  • Allows a second measurement (pH, Flow rate, Conductivity,etc.). Data from this blind unit are displayed on the main unit.
  • Mounting: wall or panel versions
  • Connected to main unit with 2 x 2-wire shielded cable (Cable length between both devices: max. 500 m)
  • RS422 and Data Logger of main unit are shared between both units