Skip to content

TCL S50 Inductive Conductivity Probe

Brand: BAMO
BAMO Mesures TCL S50 Inductive Conductivity Probe, ISME Malaysia
  • Measuring range from 10 μS/cm up to 2000 mS/cm
  • Construction: PEEK
  • Wide chemical compatibility
  • Temperature max. 125 °C
  • Low fouling probe
  • Built-in Pt100 sensor
  • Applications where high chemical resistance or high operating temperature are necessary:
    • WWTP survey
    • Concentration monitoring of acid and base (e.g.: NaOH, HNO₃, H₂SO₄)
    • Quality survey of chemicals in tank or pipeline
    • Phase separation of mixture liquid/liquid
Measuring range:  Conductivity: 10 μS/cm up to 2000 mS/cm
Cell constant:  c = 1.98 cm⁻¹
Probe material:  PEEK
Seal:  FPM
Fitting:  3/4” BSP
Ambient temperature:  –10 to +70 °C
Liquid temperature:  -20 to +125 °C
Temperature sensor:  Built-in Pt 100 sensor (Class A – acc. IEC 60751)
Pressure:  20 bar max
Protection:  IP 67 (NEMA 6)
IP 68 with immersion probe holder
Output cable version:  5 m long cable

BAMO TCL S50 probe is well adapted for measurement between 10 μS/cm up to 2000 mS/cm. It uses inductive measurement that offers many advantages. There is total galvanic insulation between the measuring loop and the liquid for reliable measurements on numerous chemicals.

The construction material, PEEK, allows a wide range of chemical compatibilities and a long lifespan. TCL S50 probe may also work at high temperatures up to 125 °C. The TCL S50 probe can be used with Bamophar 364 monitor.

  • Immersion measurement: The probe is fixed to end of probe holder for immersion, length from 500 to 2000 mm, with optional flange fitting.
  • On-line measurement: Probe is mounted on a Te, ND 50 mm.