Skip to content

Bamophar 436 Turbidity Monitor

Brand: BAMO
BAMO Mesures Bamophar 436 Turbidity Monitor, ISME Malaysia
  • Color touch screen
  • Available scales: 0.001 to 9999 FNU, FAU, NTU, mg/l, g/l
  • 2 outputs 0/4-20mA (measurement & T.°C)
  • 3 Independent relays
  • 1 Relay for alarming function
  • Options:
    • RS 422 /J-BUS + Logger
    • Extension terminal for a 2nd measurement parameter
End-user interface:  Color touch screen 4.3”, resolution 480×272 pixels
Display of measurements, menus, temperature, relay status
Configuration – Keyword protected
Measuring scales:  To set up according the turbidity transmitter in use (from 0.001 to 9999 FNU, FAU, NTU, mg/l, g/l)
Sensor signal input:  For Turbidity transmitter 4-20 mA, 2-wire or 4-wire technique
Temperature display:  Input signal for Pt 100 Ω 3-wire sensor, within the range 0 to 100 °C
Input signal for Pt 100 Ω 3-wire sensor, within the range 0 to 100 °C
Relay outputs:  4 contacts N.O., potential free
Configurable thresholds:  2 Independent thresholds, for measurement or temperature
1 Independent threshold, for measurement or temperature or to external function
1 threshold for alarming function (Temperature sensor fault) or measurement out of range
Contact initial resistance: 100 mΩ max. (voltage drop 6 V DC 1 A)
Switching power: 831 VA AC / 3 A / 277 V AC
90 W / 3 A / 30 V DC
Switching capacity (min.):  100 mA, 5 V DC (variable according to switching frequency, environmental conditions and accuracy).
Measurement output:  0/4-20 mA (max. 600 Ω) proportional to measurement
Temperature output:  0/4-20 mA (max. 600 Ω) within the range 0 to 100 °C
Measurement output:  0/4-20 mA (max. 600 Ω) proportional to flow-rate – Programmable scale
Temperature (°C)
Main power supply:  230 V AC – 50/60 Hz (others on request) – Consumption 10 VA
Models:  Panel mounting, 96×144 mm; Front IP65; Rear IP40
Wall mounting, IP65, with cable glands
Storage:  -10 to +70 °C
Operating temperature:  -5 to +50 °C
Option (RS 422 + Logger):  RS422 output, J-BUS link – Binary slave mode – 2400 to 9600 bauds
Data Logger; Record of cycle average measurement – 150 000 records max. on memory card

Bamophar 436 turbidity monitor is equipped with a color touch screen to set up the configuration and to display the turbidity, temperature and state of thresholds. Copies of measurement are available on 2 outputs 4-20 mA.

Bamophar 436 displays the turbidity value measured by one of our transmitters, to respond to process requirements.

  • Turbicube in PVC or PPH and Trubomat GAB in stainless steel, are dedicated to in-line measurement.
  • Turbisens in PVC is an immersion probe with transmitter for measurements in tanks, basins, channels.

A complete measuring system includes a Bamophar 436 monitor and a turbidity transmitter

Option: Extension terminal for a second parameter

  • Allows a second measurement (pH, Flow rate, Conductivity,etc.) (Configuration and display on the main unit)
  • Connected to main unit with 2 x 2-wire shielded cable (Cable length between both devices: max. 500 m)
  • RS422 and Data Logger of main unit are shared between both units
  • Wall or panel or DIN rail mounting: according to the model