Skip to content

CD7 Chlorine Dioxide Sensor

Brand: BAMO
BAMO Mesures CD7 Chlorine Dioxide Sensor, ISME Malaysia
  • Drinkable water, sea water
  • Surfactants: partial tolerance
  • Temperature: 50 °C max.
  • Pressure: 1 bar max.
Measured parameter:  Chlorine dioxide
Applications:  Water treatment (for water equivalent to drinkable quality) and sea water
e.g.: Bottles disinfection, CIP etc.

Surfactants: partial tolerance

Measuring system:  Closed cell with 2 electrodes and electrolyte
Supply voltage:  12 … 30 V DC (Load 500 to 900 Ω)
Output signal:  4 … 20mA, 2 screw terminals (2 x 1mm²)
No galvanic insulation
Operating temperature:  1 to 50°C
Automatic temperature compensation
Operating pressure:  1 bar max. (No vibrations, no pulsating flow)
Flow rate:  About 30 l/h
pH operating range:  Between pH 1 and pH 11
Interferences:  High incidence of O₃ on measuring signal
No incidence of Cl₂
Zero adjustment:  Not necessary (from factory)
Slope calibration:  Only 1 point with BAMOPHAR 194
Materials:  PVC-U and AISI 316 Ti (1.4571)
Dimensions:  O.D. 25 mm, length 220 mm (4-20 mA)

BAMO CD7 chlorine dioxide sensor is suitable for water treatment (for water equivalent to drinkable quality) and sea water e.g.: Bottles disinfection, CIP etc.