Skip to content

CUB-233 Versatile Converter

Brand: BAMO
BAMO Mesures CUB-233 Versatile Converter, ISME Malaysia
  • 1 Input, multi-parameters mA, V, Pt 100, potentiometric, resistor
  • Supply to the sensor
  • 2 analogue outputs
  • 2 relay outputs
  • Setting by joystick or PC
  • Linearization and taring function
  • Wide range of main supply 80 to 256 V AC 50/60 Hz; 20 to 240 V DC
  • Applications for most of all use on signal conversion:
    • Level measuring probe with potentiometric output
    • Level measuring probe, 2-wire, 4-20 mA output
    • Temperature probe with Pt 100 sensors or thermocouple
    • Zooming on input signal
    • Linearization along “up to” 100 points
    • Alarming function for all the above sensor
Display unit:  LCD, green, non-backlit
Displayed information:  Real time input value and as programmed value
Outputs as set up values and percentage
Relays status
Display adjustment:  Lighting display adjustment according to ambient temperature
Input scale factor:  Allows a zoom effect on input signal or manual or automatically
Output scale factor:  Allows a zoom effect on input signal and displayed value
Programming:  Programming through a joystick in front, 5 positions
Memory, Min. / Max.:  Logging of Min. and Max. measurements
Saved value
Possibility to store at the output, the last measured value in case of sensor failure
Offset:  Offset set up on input for any signal type
Taring function: Taring function signal inputs
Simulation:  Simulation programme actuates on analogue outputs, relays and display indedently of input value and without disconnecting the sensors neither output connections.
Output signal restrictions:  Possibility of limiting the output value
High and low limits to set up
Reference junction:  The reference junction is insured through a numerical sensor 16 bits
Input safety signal:  In case of broken loop input signal, CUB 233 produces a set up value on display and outputs
Linearization with 100 points:  Allows an output signal from a segmented input signal. E.g.: Volume of a cylindrical and horizontal tank vs. height of fluid
Linearization PTC – NTC resistors:  Allows to correct the PTC or NTC signal against segmented input signal (programming only with the software BLOG CUB)
Thresholds:  Simple mode or bandwith mode, with positive or negative safety
Set up of hysteresis and delay, independently for decreasing or increasing signals
Direct access to thresholds, memory and alarm reset
Alarm reset:  Independently on each alarm
Alarm saving:  Independently for each alarm
Other functions:  Cut Off – 1 or 10 points resolution – Comma position – Filtering – Joystick lock – Contrast adjustment of display screen

BAMO CUB-233 converter is a great solution for any applications to convert or monitor output signals from sensors. Both analogue outputs may be set up as mA or mV signals and both relay outputs may be set up all along the scale (thresholds, hysteresis and delay).