- Control of flow-rate in lubrication pipings or in any compatible skids
- Operates in all positions
- Blind controller, 1 contact
- Versions: Stainless steel and brass
- Pressure up to 350 bar
- Viscosity: 30 … 600 cSt
- Flow ranges from 0.5 up to 90 l/min
Temperature limits: | -20 to 120 °C (On request: up to 160 °C) |
Flow scale unit: | l/min of oil; Min. S.G. 0.9 |
Viscosity: | 30 to 600 cSt |
Accuracy: | ±10 % F.S. |
Pressure drop: | 0.02 to 0.4 bar |
Flow contact: | N.O. without flow |
Connector: | DIN 43650 plug-in socket IP 65 |
Brass version: | Pressure limit: BSP 1”: 250 bar; BSP ½”: 300 bar Body, fittings: Nickel plated brass Orifice plate: Nickel plated brass Spring: AISI 316 Ti (1.4571) Seals: FPM Magnet: Ferrite |
Stainless steel version: | Pressure limit: BSP 1”: 300 bar; BSP ½”: 350 bar Body, fittings: AISI 316 Ti (1.4571) Orifice plate: AISI 316 Ti (1.4571) Spring: AISI 316 Ti (1.4571) Seals: FPM Magnet: Ferrite |
BAMO DKM viscosity compensated metallic flow controller controls the flow of a liquid, free of suspended particles, having a viscosity between 30 and 600 cSt.
Operation: The fluid drives a magnetic orifice plate inside the cylindrical measuring tube. A spring balances its movement and allows to operate in all positions. A Reed contact, N.O. without flow, changes of status with the passage of the magnetic orifice plate.
With these equipment, the DKM operates independently of the pressure, even with low flow-rates.