Skip to content

DST Orifice Plate Bypass Flow Meter

DST Bypass Flow Meter, ISME Malaysia
  • Wide choice of materials
  • High volume rates of flow possible
  • Orifice plate can be installed in any position
  • No power requirement for indication
  • Easy to install
  • Measuring accuracy +/- 2 % FS
  • Scale specific to the process fluid
  • Optional:
    • Limit value switches
    • Bypass extension
Model Types:  DST-PVC: device in PVC
DST-PP: device in PP
DST-PVDF: device in PVDF
DST-½: device in steel
DST-V4A: device in stainless steel
DST-…-MSK1: with limit value switch (normally open)
DST-…-MSK12: with limit value switch (normally closed)
DST-…-MSKW: with limit value switch (change over)
DST-PVC: Ring: PVC
Orifice plate: PVC
Valves: PVC
Bypass Line: PVC
Indicator: RA77 / PSU
Glass Measuring Tube: Borosilicate glass, optional polysulphone
Float: PVC, optional 1.4571, PTFE
Gaskets: EPDM, optional FKM
Max. Temperature / Pressure (Gauge):
20 °C at 10 bar
40 °C at 6 bar
DST-PP:   Ring: PP
Orifice plate: PP
Valves: PP
Bypass Line: PP
Indicator: RA77 / PSU
Glass Measuring Tube: Borosilicate glass, optional polysulphone
Float: PP, optional 1.4571, PTFE
Gaskets: EPDM, optional FKM
Max. Temperature / Pressure (Gauge):
20 °C at 10 bar
70 °C at 2,5 bar
80 °C at 1,5 bar
DST-PVDF:  Ring: PVDF
Orifice plate: PVDF
Valves: Polysulphone / PVDF can be supplied without valves
Bypass Line: PVDF
Indicator: RA87 / PSU
Glass Measuring Tube: Borosilicate glass, optional polysulphone
Float: PVDF, optional 1.4571, PTFE
Gaskets: FKM, optional EPDM
Max. Temperature / Pressure (Gauge):
20 °C at 10 bar
80 °C at 5 bar
100 °C at 4 bar
DST-½:  Ring: S355
(Corrosion protection: epoxy paint, kiln-dried, traffic blue (RAL 5017), satin finished; Corrosion class: C2)
Orifice plate: 1.4571
Valves: Brass, Nickel-plated
Bypass Line: Steel, zinc plated
Indicator: RA65
Glass Measuring Tube: Borosilicate glass
Float: Water: 1.4571; Air: anodized aluminium
Gaskets: NBR
Max. Temperature / Pressure (Gauge):
20 °C at 10 bar
Special design: 80 °C at 5 bar
DST-V4A:  Ring: 1.4571
Orifice plate: 1.4571
Valves: 1.4571
Bypass Line: 1.4571
Indicator: RA87
Glass Measuring Tube: Borosilicate glass
Float: Water: 1.4571; Air: PTFE
Gaskets: FKM
Max. Temperature / Pressure (Gauge):
20 °C at 10 bar
Special design: 80 °C at 5 bar

DST bypass flow meter operates on the differential-pressure-bypass method. A ring with an orifice plate is installed in the pipeline between flanges. The measuring orifice leads to a constriction and causes a differential pressure. As compensation a volume flow occurs in the bypass which is displayed by a variable area flow meter. This partial flow is proportional to the flow rate in the main pipeline. The unimpeded, straight tube length has to be 6 DN before and 4 DN behind the mounting position. The partial flow can be turned on and off, as required, by installing two ball valves in the bypass line.

PVC model is frequently used in swimming-pool water technology. The models in PP and PVDF is suitable for the flow measurement of aggressive media, e.g. in water
treatment. For other fields of application there is a steel and stainless steel variant (DST ½ and DST V4A).

By installation of electrical limit value switches, which are adjustable throughout the entire measuring range, these devices can be used as detectors.

Related Articles