- Direct reading
- Accuracy ± 2 %
- For liquids or for gases
- Materials according ranges
- Adjustable contacts
Accuracy: | ± 2 % F. S. (Full Scale) |
Repeatability: | ≤ 0.25 % of reading |
Scale length: | 250 mm |
Unit: | On request |
Temperature limits: | 0 to 90 °C with Buna seals 0 to 120 ° C with FPM seals |
Fittings: | BSP-F or flanges (DIN, ANSI, etc.) |
Thread fittings: | Carbon steel, or AISI 316, or PVDF On request: Hastelloy, Titanium |
Flanges: | AISI 316, or painted carbon steel |
Measuring tube: | Borosilicate glass |
Spherical diver: | Refer to datasheet |
Conical diver: | Standard: AISI 316 L; Or Aluminum (application for air) Options: PVDF, PTFE, Hastelloy B or C, Monel or titanium |
Stops: | AISI 316 L, or PVDF On request: Hastelloy, monel |
Seals: | Standard: NBR; Or FPM |
Body: | Epoxy painted carbon steel Or AISI 304 L |
Monostable inductive contacts (Intrinsically safe version (CENELEC, EEX ib II C): | |
Repeatability: | ± 0.3 % F.S. |
Ambient temperature: | -25 to +60 °C |
Protection: | IP 67 |
Cable length: | 1 m |
Transparent protection screen: | PMMA |
Guiding rod (when specified): | AISI 316 Or same material as of the diver |
BAMO E Series variable area flowmeter measures flow rates with the diver (”float”) moving inside a calibrated conical tube. These flow indicators may be calibrated according to the fluid properties and operating conditions. They accept flow switches, inductive monostable contacts, adjustable over the entire measuring range.
The E series flow indicators are used for flow-rate reading or on gases or on liquids such as water treatment plants; manufactures (pulp industry, textile industry, etc.); chemical, pharmaceutical industries and heating or cooling plants.