Skip to content

IUNI-21 2-Channel Chlorophyll Analyzer

Brand: PROBEST
I-SYSTEM IUNI-21 2-Channel Chlorophyll Analyzer, ISME Malaysia
  • RS485 signal output
  • Optical fluorescent measurement technique
  • Identify pigment before it is affected  by potential water bloom
  • Requires no extraction or other treatment, rapid detection to avoid the impact of long shelving the water sample
  • Stable data and good repeatability
  • Direct and continuous measurement
  • Strong anti-interference ability
  • Fast response time
  • Low maintenance cost
  • Suitable for wide range of application such as water treatment plant (inlet), drinking water resources and aquacultural

C800 Series Digital Chlorophyll Sensor

Measuring range:  0 to 500 ug/L
Pressure range: ≤0.4Mpa
Measuring temperature:  0 to 45°C
Requirements:  Suggest a multipoint monitoring for the distribution of Blue-Green Algae in water that is very uneven. Water turbidity is below 50NTU.
Accuracy:  ±5% of the signal level corresponding value of 1ppb Rhodamine WT Dye
Calibration:  Deviation value calibration; Slope calibration
Communication:  RS485 (Modbus)
Dimension:  Diameter 38 mm, Length 245.5 mm
Protection:  IP68 / NEMA 6P
Sensor material:  SUS316L + PVC; Titanium alloy (optional)
Signal cable length:  Standard 10 meter
Storage temperature:  -15 to 50°C

 

 

IUNI-21 Dual Channel Analyzer

Display:  160*160 LCD with backlight
Power supply:  AC: 85-500V AC, 50/60Hz; DC: 9-36V DC (upon request)
Analogue output : 3 x 4-20mA
Relay output:  3 x relay output (programmed response parameters and value)
Communication protocol:  RS485 (Modbus)
Ambient temperature: -20 to 70°C
Operation temperature:  -15 to 60°C
Protection:  IP65 / NEMA 4X
Device weight:  1.35 kg
Device dimension:  145 (H) x 125 (W) x 162 (D) mm
Enclosure:  PA66+GF25+FR (Cover); Aluminium alloy powder (Lower casing)
Parameter:  Ammonia nitrogen

The C800 series online optical digital chlorophyll sensor’s principal the characteristics of chlorophyll A who has absorption peaks and emission peaks in the spectrum. The absorption peaks emit monochromatic light into the water, chlorophyll A in the water absorbs the energy of monochromatic light, releasing monochromatic light of emission peak of another wavelength. The light intensity emitted by cyanobacteria is proportional to the content of chlorophyll A in water.

The IUNI-21 dual channel analyzer is an effective option that can connect two digital chlorophyll sensors at the same time to reduce the cost of transmitter and installation space:

  • Field mounted dual channel analyzer with datalogger
  • Connect two sensors at one time
  • 4-20mA output
  • Relay output
  • Communication, RS485 (Modbus)
  • LCD visual display
  • User friendly and attractive operating interface

Price is indicative, consisting of 1 x IUNI-21 Universal Transmitter and 1 x C800 Digital Chlorophyll Sensor.