IUNI-21 2-Channel Low-Range Turbidity Analyzer

Brand: PROBEST
I-SYSTEM IUNI-21 2-Channel Low-Range Turbidity Analyzer, ISME Malaysia
  • RS485 signal output
  • Infrared light scattering technique
  • Stable data and good repeatability
  • Continuous and stable measurement in the water flow sampling chamber
  • Fast response time
  • Low maintenance cost

T700 Series Digital Turbidity Sensor

Measuring range:  0.01 to 100 NTU
Flow rate:  300ml/min ≤ X ≤ 700ml/min
Measuring temperature:  0 to 45°C
Accuracy:  ±2% or ±0.015NTU of the measured value, when the range is 0.001 to  40NTU;
±5% of themeasured value, when the range is 40 to 100NTU
Calibration:  Standard solution calibration; Water sample calibration;Zero calibration
Communication:  RS485 (Modbus)
Dimension:  Diameter 60 mm, Length 256 mm
Protection:  IP68 / NEMA 6P
Sensor material:  ABS + SUS316 L (body)
Acrylonitrile Butadiene Rubber (seal)
Pipe fitting:  Inlet Port: 1/4NPT
Outlet Port: 1/2NPT
Signal cable length:  Standard 3 meter (no extension)
Storage temperature:  -15 to 60°C

IUNI-21 Dual Channel Analyzer

Display:  160*160 LCD with backlight
Power supply:  AC: 85-500V AC, 50/60Hz
DC: 9-36V DC (upon request)
Analogue output : 3 x 4-20mA
Relay output:  3 x relay output (programmed response parameters and value)
Communication protocol:  RS485 (Modbus)
Ambient temperature: -20 to 70°C
Operation temperature:  -15 to 60°C
Protection:  IP65 / NEMA 4X
Device weight:  1.35 kg
Device dimension:  145 (H) x 125 (W) x 162 (D) mm
Enclosure:  PA66+GF25+FR (Cover); Aluminium alloy powder (Lower casing)
Parameter:  Low-range turbidity

The T700 series online digital low-range turbidity sensor is capable of providing continuous and stable measurement that is suitable for low range of turbidity measurement. Turbidity is measured by directing tungsten or LED light from the sensor head assembly in the water sample chamber (water flow sampling chamber) of the T700. Light scattered at 90° by suspended particles in the sample is detected by the sensor’s submerged photocell. The amount of light scattered is proportional to the amount of turbidity in the sample.

The IUNI-21 dual channel analyzer is an effective option that can connect two digital low-range turbidity sensors at the same time to reduce the cost of transmitter and installation space. It is widely used in drinking water, water treatment plant, processing plant for semiconductor and food and beverage industry for processes in pre-filtration, post-filtration, direct drinking water system, industrial production circulating water, filter centres and recycling centres:

  • Field mounted dual channel analyzer with datalogger
  • Connect two sensors at one time
  • 4-20mA output
  • Relay output
  • Communication, RS485 (Modbus)
  • LCD visual display
  • User friendly and attractive operating interface

Price is indicative, consisting of 1 x IUNI-21 Universal Transmitter and 1 x T700 Series Low Range Turbidity Sensor.