Skip to content

IUNI-21 2-Channel pH Analyzer

Brand: PROBEST
I-SYSTEM IUNI-21 2-Channel pH Analyzer, ISME Malaysia
  • Product registered with SPAN
  • RS485 signal output
  • Electrochemical pH sensor
  • Stable data and good repeatability
  • Strong anti-interference ability
  • Fast response time
  • Low maintenance cost
  • Suitable for wide range of applications such as wastewater treatment plant, chemical and biological plant, hydrology water surface monitoring etc.

P500 Series Digital pH Sensor

Measuring range:  0 to 14 pH
Pressure range: ≤0.6Mpa
Measuring temperature:  0 to 80°C
Accuracy:   ±0.01pH
Alkali Error:  0.2pH (1 mol/L Na + pH14) (25°C)
Zero Potential pH Value:  7±0.25pH (15mV)
Slope:  ≥95%
Internal Resistance:  ≤250MΩ
Response Time:  ≤10 seconds (Reach 95% of the end value) (After stirring)
Power supply:  12 VDC
Communication:  RS485 (Modbus)
Dimension:  Diameter 30 mm, Length 195 mm
Protection:  IP68 / NEMA 6P
Sensor material:  Black polypropylene cover; Ag/Agcl reference gel
Signal cable length:  Standard 10 meter
Mounting thread:  3/4” thread

IUNI-21 Dual Channel Analyzer

Display:  160*160 LCD with backlight
Power supply:  AC: 85-500V AC, 50/60Hz
DC: 9-36V DC (upon request)
Analogue output : 3 x 4-20mA
Relay output:  3 x relay output (programmed response parameters and value)
Communication protocol:  RS485 (Modbus)
Ambient temperature: -20 to 70°C
Operation temperature:  -15 to 60°C
Protection:  IP65 / NEMA 4X
Device weight:  1.35 kg
Device dimension:  145 (H) x 125 (W) x 162 (D) mm
Enclosure:  PA66+GF25+FR (Cover); Aluminium alloy powder (Lower casing)
Parameter:  pH

The P500 series pH sensor uses a composite electrode which is a combination of glass and reference electrode to measure pH value of liquid. The potential of the reference (internal) in glass combination electrode is constant regardless of pH measured in liquid. During the measurement, H+ concentration changes when there is a difference between the stable potential of reference and potential measured liquid. It is measured by the voltmeter and apply as a pH measurement result.

The IUNI-21 dual channel analyzer is an effective option that can connect two digital pH sensors at the same time to reduce the cost of transmitter and installation space:

  • Field mounted dual channel analyzer with datalogger
  • Connect two sensors at one time
  • 4-20mA output
  • Relay output
  • Communication, RS485 (Modbus)
  • LCD visual display
  • User friendly and attractive operating interface

Price is indicative, consisting of 1 x IUNI-21 Universal Transmitter and 1 x P500 Digital pH Sensor.

This product is registered with SPAN.