- All-plastic versions
- Integrated transmitter and connection for test button
- No moving parts
- For retention on storage tanks
- NPN / PNP interfaces
Detection: | Capacitive high-frequency sensor, fail-safe detector |
Ambient temperature: | -20 to +60 °C |
Operating pressure: | Atmospheric; Limits: 0.8 to 1.1 bar |
Housing head: | PBT, fibre-glass reinforced |
Fittings: | Refer to datasheet |
Power supply: | 15 to 27 V DC |
Consumption: | < 1 W |
Materials: | Mounting bracket or cap: PVC Probe: PVC for O.D. 25; PE for O.D. 40 |
Outputs: | Potential-free Reed contact for low voltage (Normally closed, it opens when alarm occurs) – Rated: Max. 50 V AC / DC, Max. 0.5 A, Max. 10 VA, convenient for operating with a coupling relay or PLC, signaling device TC4 / TC1 or CST unit. 2-wire alarm output reporting with transmitter MAXIMAT SHR C Note: Simultaneous use of both outputs is not possible. |
Terminals: | Screw terminals, cable max. 2.5 mm² |
Additional function: | Connection of an external test button (potential-free contact), for a complete diagnostic of the device integrity (connection loops, electronics). |
Connection options: | Alarm units: MAXIMAT TC1 / TC4 Coupling relay: CST Transmitter: MAXIMAT SHR C Automation with PLC |
BAMO Maximat LW CX compact leak detectors are used to detects leakage of containers, outside the container, leaks of water polluting liquids. When an electrically conductive liquid comes into contact with the detector probe, the integrated electronics respond by interrupting the continuous output signal. By interrupting the signal, audible and visual alarms are triggered.