- Continuous level measurement
- The sensor is not in contact with liquid
- Reliable even with aggressive, viscous, dirty or crystallizing liquids
- Stable measurement with a venting module
- High measuring accuracy
| Power supply: | 12 to 28 V DC; max. 5% effective ripple |
| Ambient temperature: | -20 to +60 °C |
| Liquid temperature: | PVC: 0 to +60 °C PP: 0 to +90 °C |
| Output signal: | 4-20 mA; 2-wire transmitter |
| Head housing: | PBT, glass fiber reinforced Protection: IP 65 according EN 60 529 |
| Process connection: | Head with fixed measuring tube Ø20 (standard) Head prepared for tube connection Ø20 Head with hose fitting and mounting bracket |
| Measuring cell: | Ceramic with EPDM sealing Capacitive type with temperature compensation Measuring ranges, turndown 1:5 available for the following scales (of WATER): |
| Accuracy: | < 1% F.S. |
| Materials: | Fitting BSP 2”: PVC or PP Measuring tube: Same as fitting (or PVC or PP) Measuring hose: EPDM Sensor seal: EPDM |
| Connection for venting function: | Female thread BSP ¼” and hose nipple for Ø 4×1 mm hose |
| Accessories: | Automated venting module MEMPRO BL |
BAMO Mempro is designed for continuous level measurement for pressure-free containers, aggressive liquids and storage tanks. It works according to the hydrostatic pressure measuring principle. The output signal corresponds to the pressure of the atmosphere inside the measuring tube; The ceramic sensor is not touched by the liquid.
Price indicated is for standard process connection (head with fixed measuring tube Ø20). Please contact us for other specifications.