Skip to content

Mudsonic Underwater Settled Solids Detector

Brand: BAMO
BAMO Mesures Mudsonic Underwater Settled Solids Detector, ISME Malaysia
  • Detection of settled solid particles in water
  • Level monitoring with ultrasonic detector
  • Output: 2 limit contacts, 1 fault contact
  • Adjustable timer
  • Adjustment along 3 measuring ranges (For sludge densities within 50 to 250 g/l )
  • Applications:
    • Iron filings detection
    • Salt detection in brine tank
    • Sludge height monitoring in thickeners, primary clarifiers and industrial processes (sludges with iron hydroxide, high density slurry, etc.)
Operating unit Mudsonic MF:  
Power supply:  Model MF G: 100 to 255 V AC – 50/60 Hz
Model MF D: 10 to 30 V DC and 12 to 24 V AC
Consumption:  1 to 5 W
Ambient temperature:  -10 to +45 °C
Relay outputs:  2 contacts, 1 threshold, potential-free (N.O.) (Limit exceeded, below the limit)
1 potential-free contact, fault alarm (N.O.)When the supply voltage is off or in case of power failure, all contacts are open.
Switching power:  250 V AC, 3A / 30 V DC, 1 A
Caution: The contacts are not protected against overload. Provide an external protective device.
Housing dimensions:  22.5 x 100 x (h)122 mm
DIN rail:  35 x 7.5 mm (DIN EN 60715)
Protection:  IP 40
Electrical connections:  Screw connectors; Cables 1.5 mm² max.
Display:  2½ digit LED, 5×7 dot matrix display
1 Blue LED, relay energized
3 Yellow LEDs, measuring range (LOW / Medium / HIGH)
Settings:  Through a rotary switch on front
Delay:  Adjustable from 0.1 up to 9.9 s

Probe Mudsonic TS: 
Detector material:  PVC
Cable:  TPK, 10 m long, shielded, 2 x1 mm²
Other cable materials and lengths request ( PVC, oil and hydrocarbons-proof, etc.)
(Max. length 50 m)
Dimensions:  145 x 90 x 25 mm
Protection: IP 68 acc. EN 60529
Measuring principle:  Ultrasonic signal attenuation
Operating temperature:  -20 to +45 °C

BAMO Mudsonic system includes a Mudsonic TS immersion probe and a Mudsonic MF operating unit.

The detection is done between emitter and receiver of ultrasonic waves. The probe evaluates the concentration of solid particles by attenuation of the signal. The probe is immersed at a fixed height in the tank; It triggers a switch when the concentration (predefined) is reached (sludge level rising by settlement). The trigger point and timer are adjustable on site (real operating conditions).