RA60/FA60 High Flow Range Glass Variable Area Flow Meter

Brand: BAMO
BAMO Mesures RA60/FA60 High Flow Range Glass Variable Area Flowmeter, ISME Malaysia
  • Direct reading on calibrated tube
  • Range: From 0.1 l/h up to 1,500 m³/h
  • Accuracy ±2 %
  • For liquid or for gas
  • Materials: Glass, Steel or Stainless Steel
  • Adjustable contacts
  • Analogue output 4-20 mA or 0-10 Volt
  • ATEX version
  • Suitable for: Water treatment, industrial process (paper mill, textiles etc.), chemical and pharmaceutical industries, heating and cooling plants
Nominal pressure:  PN 10 at 20 °C
Pressure limits:  Refer to the table ”Measuring ranges” in datasheet
Operating temperature:  Max. 80 °C depending of the version (Option: 100 °C)
Scale factor:   1:10
Accuracy class:  According to VDE/VDI 3513 page 2 (08/2008)
Error limit (G):  1.6 %
Linear limit (qG): 50%
Fittings / RA 60:  Union, 2 pieces
Inner cylindrical insert,
thread according to DIN EN 10226-1 (ISO 7-1)
Raccords / FA 60:  Flange PN 10 according to DIN EN 1092-1

MATERIALS

Steel case:  Steel Pipe, P235
Ends / RA 60:  S355 (size 19), EN-GJL-200 (size 30 – 36),
Cast aluminum from size 43 and larger
Threaded seal:  Malleable cast iron, zinc plated
Flanges / FA 60:   S355
Measuring tube:  Borosilicate glass
Protective screen:  Perspex
Seals:  NBR (Options: FPM, EPDM, FFKM)
Floats for liquids ¹⁾:  AISI 316 Ti (Options: PVC, PP, PVDF or PTFE with weighted core)
Floats for gases ¹⁾:   Anodized aluminum (Options: PVC, PP, PTFE, PVDF or AISI 316 Ti)
Floats for versions with contacts ¹⁾:  For liquids: AISI 316 Ti with magnetic core
For gas: PVC with magnetic core
Other materials on request

Note: 1) Small floats are not guided. With guide rod from size 30 and greater (Detailed description on request)

BAMO RA60/FA60’S measuring principle is that of the variable area flowmeter, the float is moved by the fluid inside a calibrated conical glass tube. The borosilicate glass conical is inside a steel case with a transparent reading window.

Versions:

  • RA60 Fittings: Unions BSP-F: ¼” to G 3”
  • FA60 Fittings: Flange ND 10 to ND 200
  • RA/FA60-MSK1: With N.C. bistable contact
  • RA/FA60-MSK2: With N.O. bistable contact
  • RA/FA60-MSKW: With bistable changeover contact
  • RA/FA60-EM: * With analogue output 4-20 mA or 0-10 Volt (Only on model sizes 100 and 110)
  • RA/FA60-Ex: ATEX, explosion-proof version

Contacts: These flowmeters can be equipped with a magnetic float and Reed contacts, trigger points adjustable over the entire measuring range.

Output 4-20 mA or 0-10 Volt: The transmitter is connected to a Hall effect, linear signal ruler. The analogue signal is the image of the float position. The transmitter is connected via an M12 connector. This output is useful for applications using a PLC. The device is compact with a high level of repeatability.