- Direct reading on calibrated tube
- Range: From 0.1 l/h up to 1,500 m³/h
- Accuracy ±2 %
- For liquid or for gas
- Materials: Glass, Steel or Stainless Steel
- Adjustable contacts
- Analogue output 4-20 mA or 0-10 Volt
- ATEX version
- Suitable for: Water treatment, industrial process (paper mill, textiles etc.), chemical and pharmaceutical industries, heating and cooling plants
Nominal pressure: | PN 10 at 20 °C |
Pressure limits: | Refer to the table ”Measuring ranges” in datasheet |
Operating temperature: | Max. 80 °C depending of the version (Option: 100 °C) |
Scale factor: | 1:10 |
Accuracy class: | According to VDE/VDI 3513 page 2 (08/2008) |
Error limit (G): | 1.6 % |
Linear limit (qG): | 50% |
Fittings / RA 60: | Union, 2 pieces Inner cylindrical insert, thread according to DIN EN 10226-1 (ISO 7-1) |
Raccords / FA 60: | Flange PN 10 according to DIN EN 1092-1 |
MATERIALS
Steel case: | Steel Pipe, P235 |
Ends / RA 60: | S355 (size 19), EN-GJL-200 (size 30 – 36), Cast aluminum from size 43 and larger |
Threaded seal: | Malleable cast iron, zinc plated |
Flanges / FA 60: | S355 |
Measuring tube: | Borosilicate glass |
Protective screen: | Perspex |
Seals: | NBR (Options: FPM, EPDM, FFKM) |
Floats for liquids ¹⁾: | AISI 316 Ti (Options: PVC, PP, PVDF or PTFE with weighted core) |
Floats for gases ¹⁾: | Anodized aluminum (Options: PVC, PP, PTFE, PVDF or AISI 316 Ti) |
Floats for versions with contacts ¹⁾: | For liquids: AISI 316 Ti with magnetic core For gas: PVC with magnetic core Other materials on request |
Note: 1) Small floats are not guided. With guide rod from size 30 and greater (Detailed description on request)
BAMO RA60/FA60’S measuring principle is that of the variable area flowmeter, the float is moved by the fluid inside a calibrated conical glass tube. The borosilicate glass conical is inside a steel case with a transparent reading window.
Versions:
- RA60 Fittings: Unions BSP-F: ¼” to G 3”
- FA60 Fittings: Flange ND 10 to ND 200
- RA/FA60-MSK1: With N.C. bistable contact
- RA/FA60-MSK2: With N.O. bistable contact
- RA/FA60-MSKW: With bistable changeover contact
- RA/FA60-EM: * With analogue output 4-20 mA or 0-10 Volt (Only on model sizes 100 and 110)
- RA/FA60-Ex: ATEX, explosion-proof version
Contacts: These flowmeters can be equipped with a magnetic float and Reed contacts, trigger points adjustable over the entire measuring range.
Output 4-20 mA or 0-10 Volt: The transmitter is connected to a Hall effect, linear signal ruler. The analogue signal is the image of the float position. The transmitter is connected via an M12 connector. This output is useful for applications using a PLC. The device is compact with a high level of repeatability.