- For liquids and gases
- Direct reading on a calibrated tube
- Ranges from 0.5 l/h up to 160 m³/h
- Materials: Glass, steel or stainless steel
- Adjustable limit value switches
- Analogue output: 4-20 mA or 0-10 V
- ATEX version on request
- Suitable for: Water treatment, industrial process (paper mill, textiles etc.), chemical and pharmaceutical industries, heating and cooling plants
Nominal pressure: | PN 10 at 20 °C |
Pressure limits: | Refer to the table ”Measuring ranges” in datasheet |
Operating temperature: | Max. 80 °C (Option : 100 °C) |
Scale factor: | 1:10 |
Accuracy class: | According to VDE/VDI 3513 page 2 (08/2008) |
Error limit (G): | 1.6 % |
Linear limit (qG): | 50% |
Fittings / RA 65: | Unions, 2 pieces Inner cylindrical insert, thread according to DIN EN 10226-1 (ISO 7-1) |
Fittings / FA 65: | Flanges PN 10 according to DIN EN 1092-1, other fittings on request |
Corrosion protection: | Epoxy coating, glossy blue (RAL 5017) |
Corrosion class: | C2 |
MATERIALS
Steel case: | Steel Pipe, P235, Option PVC lining ²⁾ |
Ends / RA 65: | S355 for sizes 19 to 36; Aluminum for size 43; Option PVC lining ²⁾ |
Flanges / FA 65: | S355; Option: with PVC lining ²⁾ |
Reading tube: | Borosilicate glass |
Protective screen: | Perspex |
Gaskets: | NBR; Options: FPM, EPDM, Silicone |
Floats for liquids ¹⁾: | AISI 316 Ti (1.4571) (Options: PVC, PP, PVDF, PTFE) |
Floats for gases ¹⁾: | Anodized aluminum (Options: PVC, PP, PTFE, PVDF, AISI 316 Ti (1.4571) |
Floats for use of limit value switches ¹⁾: | AISI 316 Ti (1.4571) with magnetic core for liquids; PVC with magnetic core for gases Other materials on request |
Note:
1) Floats of small sizes are non-guided. Size 30 and larger: Partly with guiding float rod, detailed table available on request.
2) PVC lining: All wet parts (excepted the glass tube) are of PVC. Protection of all parts in contact with media
BAMO RA65/FA65’s measuring principle is that of the variable area flowmeter, the float is moved by the fluid inside a calibrated conical glass tube. The borosilicate glass conical tube is inside a steel case with a transparent reading window.
Versions:
- RA65: Fittings: Unions, BSP-F from ¼” up to 3”
- FA65: Flanges from ND10 up to ND65
- RA/FA65-MSK1: With bistable contact N.C.
- RA/FA65-MSK2: With bistable contact N.O.
- RA/FA65-MSKW: With bistable changeover contact
- RA/FA65-EM: With analogue output 4-20 mA
- RA/FA65-Ex: Explosion proof ATEX version
Limit switches: These flowmeters can be equipped with a magnetic float and Reed contacts, trigger points adjustable over the entire measuring range.
Analogue output 4-20 mA or 0-10 V: The transmitter is connected to a Hall effect linear signal ruler. The analogue signal is the image of the float position. The transmitter is connected via an M12 connector. This output is useful for applications using a PLC. The device is compact with a high level of repeatability.