- Direct reading on a calibrated tube
- Body: PVC / Reading tube: Glass
- For agressive fluids
- Fittings: Unions or flanges
- Adjustable limit value switches
- Suitable for: Water treatment, industrial process (paper mill, textiles etc.), chemical and pharmaceutical industries, heating and cooling plants
Nominal pressure: | PN 10 at 20 °C |
Temperature vs. pressure: | PVC: Max. 40 °C / 6 bar PP: Max. 80 °C / 1.5 bar PVDF: Max. 80 °C / 5.5 bar |
Operating pressure: | Refer to the table ”Measuring ranges” in datasheet |
Scale factor: | 1:10 |
Accuracy class: | According to VDE/VDI 3513 page 2 (08/2008) |
Error limit (G): | 1.6 % |
Linear limit (qG): | 50% |
Fittings / RA77: | Unions for solvent welding (DIN 8063) (Option: Thread according DIN EN 228 T1) |
Fittings / FA77: | Flanges PN 10 according to DIN EN 1092-1, other fittings on request |
MATERIALS
Protection case: | Grey PVC tube, with reading window |
Fittings and inserts RA77: | PVC (Options: PP, PVDF) |
Flanges / FA77: | PVC (Options : PP, UP-GF) |
Reading tube: | Borosilicate glass |
Protective screen: | Perspex |
Seals: | EPDM (Option: FPM) |
Floats for liquids ¹⁾: | Red PVC, metalic core |
Floats for gases ¹⁾: | Red PVC (Options: Anodized aluminium, PP, PVDF) |
Floats for use of limit value switches ¹⁾: | Red PVC rouge, with built-in magnet |
Note: 1) With guiding rod for size 30 and greater (details on request)
BAMO RA77/FA77’s design, plastic body and glass tube, makes them particularly suitable for aggressive fluids and corrosive environment. The measuring principle is that of the variable area flowmeter, the float is moved by the fluid inside a calibrated conical glass tube. The borosilicate glass conical tube is inside a plastic protection case with a transparent reading window.
Versions:
- RA77: Unions for solvent welding, ND10 to 80
- FA77: Flanges ND 10 to 80
- RA/FA77-MSK1: With bistable switch N.C.
- RA/FA77-MSK2: With bistable switch N.O.
- RA/FA77-MSKW: With bistable changeover switch
Limit switches: These flowmeters can be equipped with a magnetic float and Reed contacts, trigger points adjustable over the entire measuring range.