- For level control
- Applications with conductive liquids
- 1 to 5 Detection electrodes
- Level regulation with relays ES2001
- Applications:
- Level control in open or closed vessels
- Alarm for excess or lack of liquid (leak detection, empty piping, dry-pump prevention, etc.)
- Fill or drain function with ES2001 relay
Electrodes: | Up to 5 rods, AISI 316 L, Ø 4 mm |
Electrodes length: | 500 mm / 1000 mm / 1500 mm / 2000 mm (Please specify length) |
Fitting: | PP or AISI 316 |
Head housing: | PBT glass fiber reinforced, IP 65 (EN 60 529), cable gland M20 x 1 |
Option: Partial insulation: | Polyolefin (heat schrinkable) To avoid false alarms by conductive bridge through the medium between electrodes or if the electrodes are long and can touch each others. |
Temperature limits: | Ambient: -20 to +60 °C Liquid: -5 to +100 °C (restrictions apply according the chemical) |
Pressure limits: | 6 bar at +20 °C 1 bar at 100 °C Other pressure limits: On request |
Installation: | Vertical on top of tank; Never install horizontally |
BAMO STE level probe in combination with a relay ES2001 detects the level of electrically conductive liquids. According to the model, up to 5 levels may be triggered (using the tank as the reference electrode).
Provide a reference electrode if the tank is made of insulating material. These STE probes are not suitable for liquids with hydrocarbons or grease or for any other application where an insulating layer may deposit on the electrodes.
Refer to datasheet for specifications. Pricing varies according to specifications, number of rod, rod length and rod insulation.