Turbiswitch GS5 Controller

Brand: BAMO
BAMO Mesures Turbiswitch GS4 Controller, ISME Malaysia
  • Cost-effective turbidity controller
  • Adjustable threshold along 3 ranges ( Low / Medium / High )
  • Adjustable time delay and hysteresis
  • 2 contacts (N.O.), potential free
  • 1 fault contact (N.O.), potential free
  •  Applications:
    • Breakthrough monitoring of filter-presses; ultrafiltration; reverse osmosis
    • Monitoring of centrifuges / separators; pollution in condensate; process water / wastewater
    • Control of phase separation on product / clear phase
    • Sludge level detection in sedimentation basin, sedimentation containers
Supply power:  1) 100 to 240 V AC 50/60 Hz (Turbiswitch GS5 G) or
2) 10 to 30 V DC and und 12…24 V AC (Turbiswitch GS5 D)
Power xonsumption:  1 to 5 W
Ambient temperature:  -10 to +45°C
Output relays:   2x Contacts N.O., potential free
(Trigger point -turbidity value- to set as limit exceeded or below limit)
1x Fault contact N.O., potential freeNote: All contacts are open when supply power is switched off.
Output relay switching capacity:   250 V AC, 3 A / 30 V DC, 1 A

Note: Contacts are not protected against overload; Provide an external protective device.

Cabinet: DIN rail mounting:  Dimensions 22.5 x 100 x 122 mm
DIN rail EN 60715:  Dimensions: 35 x 7.5 mm
Protection:  IP 40
Connections: On screw terminals, max. 1.5 mm²
Limit value setting:  0 to 100 % on each 3 measuring ranges (depends of solid content)

LOW: per step of 5 %; MEDIUM: per step of 2 %; HIGH: per step of 1 %

Hysteresis:  Adjustable from 1 to 25 % of set limit value
Cable, maximum length to sensor:  Recommended Max. 100 m
Display:  2½ , LED matrix display, 5×7 pixe
Settings:  Rotary / pushbutton selector on front panel
Switching delay :  Adjustable from 0.1 to 9.9 s

BAMO Turbiswitch GS5 with one of its associated probes or cells, operates turbidity measurements for evaluation of solid content of a liquid. The turbidity signal is read out as a limit value (adjustable ) via the controller GS5.
Turbidity measurement is based on the principle of optical attenuation of transmitted light, i.e. depends directly on the amount of undissolved solids in the liquid. Pulse infrared light makes the measurement not affected by ambient light. If the measured turbidity value is exceeding or below the trigger point value, the output relay in the Turbiswitch GS5 is actuated in accordance with the settings.

A turbidity control system consists of:

  • A converter Turbiswitch GS5 + an immersion probe CP5 or
  • A converter Turbiswitch GS5 + an in-line measuring cell Turbiswitch GA

Turbiswitch GA measuring cells are made of plastic or of stainless steel, and are for installation in piping from DN15 to DN125.