![BAMO Mesures U6 Orifice Plate Flow Indicator, ISME Malaysia](https://i0.wp.com/ismesb.com/Gamma/wp-content/uploads/2023/02/110004-U6-Orifice-Plate-Flowmeter.jpg?fit=800%2C800&ssl=1)
- Mounting in all positions
- Construction: cast iron or stainless steel
- For pipes from DN 40 up to 300 mm
- Scale amplification from 2 to 10
- Accuracy: ± 2.5 %
- Optional: High or/and Low flow switches (on request)
Measuring range: | 1 to 1600 m3/h [Water at 20°C] 180 to 200 000 Nm3/h [normo m3/h of air] |
Accuracy: | ± 2.5% full scale |
Repeatability: | ± 0.5% reading |
Scale amplification: | From 2 to 10 – Linear scale |
Temperature limits: | 0 to 90°C, sealing in Buna 0 to 120°C, sealing in FPM |
Pressure limit: | 21 bar as a maximum |
Wetted parts: | Cast iron and brass (standard) Stainless steel 316 (on request) |
Diaphragm: | Stainless steel 316 |
Flow indicator: | Borosilicate glass tube |
Diver: | Stainless steel 316 SS (liquids) Aluminium (gases) |
Thrusts: | Stainless steel 316 |
Sealing: | O-rings in Buna N as standard; FPM on request |
Options (on request): | |
Alarm contacts: | (low or high flow rate) |
Inductive contact: | Mono or bi-stable |
Operating temperature: | Ambient from -25°C to 60°C |
Protection: | IP 67 |
Protection relay: | Relay S112A |
BAMO U6 orifice plate flow indicators are specifically designed for the measurement of high flow rates. They are suitable for pipes with a diameter equal or over 2″. The direct reading is done on a variable area flow meter. For an optimal accuracy, the diaphragm characteristics are calculated against the process parameters.