| Power supply: | 230 V AC, 50 Hz 24 V DC |
| Voltage tolerance: | ± 10% according to VDE 0580 |
| Consumption: | 230 V AC, 50 Hz: 6.5 VA 24 V DC: 5 W |
| Duty cycle: | 100 % |
| Response time: | Opening: 30 to 150 ms Closing: 50 to 1000 ms |
| Function: | Normally closed (N.C.) |
| Bore size: | 15 to 50 mm |
| Pressure limits: | 0.3 to 6 bar |
| Mounting position: | Coil in upright position |
| Diaphragm and pilot diaphragm: | EPDM or FPM |
| Body: | PVC: Socket ends for solvent welding PPH: Socket ends for fusion welding PTFE: BSPF |
| Ambient temperature: | Max. 50 °C |
| Fluid temperature: | Max. 50 °C |
| Viscosity: | Up to about 38 cSt |
| Protection: | IP 65 (connector fitted) or version EEXm II T4: on request |
| Connector: | Plug in socket DIN 43650, cable gland PG 9 |
BAMO VMM T4 manual diaphragm valves can be used in the most demanding applications. The different materials available allow the use with many chemicals, corrosives, in pipings for aggressive and/ or polluted liquids. The replacement of the diaphragm and wet seals is done without special tools. These valves are equipped with a secure and padlockable handwheel.