T&C UOL Ultrasonic Open Channel Flow Meter

Recently, our Technical team conducted a T& C (testing & commissioning) for the I-SYSTEM UOL Ultrasonic Open Channel Flowmeter at a STP (sewage treatment plant) in Johor. This is an onsite process to examine that the flow meter is installed and measuring accurately. 

Requirements

  • Instrument: UOL Ultrasonic Open Channel Flowmeter
  • Medium: STP effluent
  • Installation configurations: 9” parshall flume
  • Services:
    • To ensure that the non-contacting sensor is mounted correctly above the parshall flume
    • To ensure that the flowmeter is operating correctly when power up
    • To ensure the flowmeter is measuring accurately under optimal operating conditions and installation method

Solutions

  • The open channel flow meter is power up to check if the display screen and buttons are all in working conditions
  • Ensure that the flow sensor is installed in the flow stream at a location where there is no disruption of steady flow by upstream or downstream blockage
  • Sensor height is adjusted to achieve optimal result
  • The installation height and the water level is measured. The flow reading is observed and is calculated using the formula provided by the parshall flume discharge table
  • Different water levels were observed to ensure consistency in flow reading
  • An I-SYSTEM service report is provided for documentation purposes